Anytime 4 CGM-Yuwell-POCTech

We value your privacy. When visiting our website, please agree to the use of all cookies. For more information on how we process your personal data, please visit: Privacy Policy

  • c2_banner_pc.webp

    Anytime 4 CGM

    An all-in-one CGM system with up to 16 days of sensor wear and glucose readings every 3 minutes.

Why Anytime 4

Designed to support flexible, connected glucose monitoring through extended sensor wear, optional user calibration and a reusable modular design.

  • 0c_icon5.svg

    Up to 15 Days of Wear

  • c1_bc_02.svg

    Readings Every 3 Minutes

  • c1_bc_01.svg

    Factory Calibrated with Optional User Calibration

  • c1_bc_03.svg

    Customizable Glucose Alerts

  • c1_bc_05.svg

    Real-Time Data Sharing with Caregivers and Healthcare Professionals

  • c1_bc_04.svg

    Economical and Eco-Friendly Modular Design

c2_img_01.webp

Beyond Data,Toward Better Health

Your continuous glucose data is more than just numbers-it’s a window into your body.

See how food,exercise,and sleep truly affect you.Track trends,spot patterns,and generate shareable reports-all from the app.

Simple,smart,and always with you.


  • pp01.jpg
  • pp02.jpg
  • pp03.jpg

Anytime 4 Specifications

  • c_icon1.svg
    MARD Value
    8.68% ¹
  • c_icon2.svg
    Intended User
    ≥18 years old
  • c_icon3.svg
    Sensor Wear Duration
    15 days
  • c_icon4.svg
    Reading Interval
    3 mins
  • c_icon5.svg
    Warm-Up Time
    60 mins
  • c_icon6.svg
    Sensor Weight
    6.5 g
  • 6aabf56f3ba95.svg
    Water Resistance
    IP 58
  • c1_bc_07.svg
    Bluetooth Transmission Range
    6m
  • c_icon4.svg
    Shelf Life
    Sensor: 1 year; Transmitter: 2 years

*Up to 15 days of sensor wear and glucose readings every 3 minutes. Product features, indications, calibration modes and availability may vary by configuration and country. Please refer to the applicable Instructions for Use.

†The sensor is single-use; only the transmitter is reusable. Follow the Instructions for Use for transmitter care, reuse limits and replacement.

‡Routine calibration is not required in factory-calibrated mode. Where supported, optional user calibration must follow the Instructions for Use. A blood glucose check may still be required if symptoms do not match sensor readings or when instructed by the system.

§Alerts require a compatible smartphone, supported app and operating system, Bluetooth connectivity, enabled notifications and appropriate settings. Data sharing requires user authorization, compatible devices/services and internet connectivity. Data may be delayed or interrupted. Alerts and shared data are not intended for emergency monitoring.

¶Clinical performance results apply to the specific device model, study population and calibration conditions evaluated. 

1 Reference: Zhang M. et al. Performance and Safety of a 15-Day Real-Time Continuous Glucose Monitoring System in Chinese Adults With Diabetes: A Multicenter Trial. J Diabetes Sci Technol. 2026 Jun 12:19322968261445103. doi: 10.1177/19322968261445103.

The Anytime 4 CGM System must be used in accordance with the applicable Instructions for Use. Do not ignore symptoms or delay medical care based on sensor glucose readings. If symptoms do not match readings, perform a blood glucose check as instructed. Follow the requirements for the selected calibration mode. Make treatment decisions only in accordance with the approved product labeling and guidance from your healthcare professional.