-
Pivotal Studies
-
Clinical & Scientific Studies
-
Pivotal Studies
-
Performance of the Fifth Generation of a 16-Day Continuous Glucose Monitoring System in Adults with Diabetes.
Chang S, et al.
Performance of the Fifth Generation of a 16-Day Continuous Glucose Monitoring System in Adults with Diabetes.
Diabetes Technol Ther. 2026 Jan 23:15209156261416870.doi: 10.1177/15209156261416870
Objective: Evaluate Efficacy and Safety of Yuwell Anytime 5Pro CGM System in People with Diabetes
Research design and methods: Multi-centre prospective study, Adult participants with type 1 and type 2 diabetes at age of 22-77 years, diagnosed with diabetes 1 to 48 years ago, with BMI between 16.9 to 35.9. Readings from Anytime 5Pro CGM matched with readings from reference laboratory device.
Key outcomes:· Overall sensor survival: 98.96%. No technical device malfunctions reported
· 100% of sensors were successfully inserted and activated
· Overall MARD: 8.58%
· Stable system performance across glucose ranges with MARD : 7.14% <54mg/dL; 9.00% 81-180mg/dL; 7.28% >181mg/dL.
· Stable system performance across sensor wear with MARD: 8.57% at the beginning; 8.30% in the middle; and 8.88% at the end of 16 days sensor wear.
· True alert rates in factory calibration mode for hypoglycemia: 94.34%; for hyperglycemia: 95.49%.
· 99.99% of readings were safe for treatment decisions and/or would not lead to inappropriate treatment (within Zone A+B of Consensus Error Grid)
· iCGM (integrated CGM) metrics met
· No Serious or Unanticipated Adverse Events observed
· Users evaluation of the system: 76.39% Excellent; 19.44% Good; 4.17% Fairly good
Conclusions:
The Yuwell Anytime 5Pro CGM System showed high performance with stable accuracy and a favourable safety profile. The system met the iCGM performance criteria. Positive participant feedback further supported strong usability and satisfaction.
-
Performance and Safety of a 15-Day Real-Time Continuous Glucose Monitoring System in Chinese Adults With Diabetes: A Multicenter Trial
Zhang M. et al.
Performance and Safety of a 15-Day Real-Time Continuous Glucose Monitoring System in Chinese Adults With Diabetes: A Multicenter Trial.
Journal of Diabetes Science and Technology. 2026;0(0). -
A Multi-center, Self-Matched Positive Controlled Clinical Investigation Report of Continuous Glucose Monitoring System for the Efficacy and Safety of Real-Time Monitoring of Glucose Concentration in Interstitial Fluid in Patients with Diabetes
Lingong J. et al.
A Multi-center, Self-Matched Positive Controlled Clinical Investigation Report of Continuous Glucose Monitoring System for the Efficacy and Safety of Real-Time Monitoring of Glucose Concentration in Interstitial Fluid in Patients with Diabetes.
Poctech-QX202206 / V1.0, June 15, 2022. Data on File.
Pending publication
-
-
Clinical & Scientific Studies
-
Post-Market Clinical Follow-Up of the CT3 Series Continuous Glucose Monitoring System: A 14-Day Observational Study Assessing Accuracy, Safety, and Glucose Control in Patients with Type 1 and Type 2 Diabetes Mellitus.
Pirags V. et al.
Post-Market Clinical Follow-Up of the CT3 Series Continuous Glucose Monitoring System: A 14-Day Observational Study Assessing Accuracy, Safety, and Glucose Control in Patients with Type 1 and Type 2 Diabetes Mellitus.
MDCE-TPMW044 2024. Data on File.
Pending publication -
Accuracy and performance of the Yuwell Anytime CT3 continuous glucose monitoring device.
Lancaster M. et al.
Accuracy and performance of the Yuwell Anytime CT3 continuous glucose monitoring device.
Br J Nurs. 2026 Feb 19;35(4):192198. -
Blood Glucose Anomaly Correction and Personalized Short-Term Prediction Based on Continuous Glucose Monitoring Data.
Jiang Z. et al.
Blood Glucose Anomaly Correction and Personalized Short-Term Prediction Based on Continuous Glucose Monitoring Data.
IEEE Sensors Journal 2025 Oct 1; 25(19):36316-36331, -
The role of combined training timing strategies in mitigating the dawn phenomenon in older adults with type 2 diabetes in Nanjing, China: a randomized controlled trial.
Yibo G. et al.
The role of combined training timing strategies in mitigating the dawn phenomenon in older adults with type 2 diabetes in Nanjing, China: a randomized controlled trial.
Preventive Medicine Reports, Volume 65, 2026, 103456, ISSN 2211-3355
-